Send OEM number, quantity, destination, or photos. We will reply with quotation, lead time, and fitment notes.
Fitment checkOEM number, engine model, and machine model confirmation.
Manual quotePrice, MOQ, stock, lead time, and replacement options.
Export supportPacking notes, mixed order support, and shipping details.
Product Details
Product Overview
This high-quality 12V Fuel Shut-Off Solenoid Valve, identified by OEM part number U85206452, is specifically designed for the Perkins 402d, 403c, 403d, and 404c series diesel engines. As a critical component in the engine’s fuel system, this solenoid valve ensures precise and reliable engine shutdown by cutting off the fuel supply when the ignition is turned off.
Manufactured to meet OEM specifications, this solenoid valve is a direct-fit replacement for your Perkins engine, restoring proper fuel control and preventing engine run-on or fuel waste. Commonly used in construction, industrial, agricultural, genset, marine, and material handling equipment, it is an essential part for maintaining operational safety and efficiency.
Please verify your engine model and existing part number to ensure compatibility before purchase.
Key Features & Benefits
Precise Fitment: Engineered as a direct replacement for the Perkins U85206452 solenoid, ensuring a hassle-free installation without modifications.
Reliable 12V Operation: Designed for standard 12-volt electrical systems found in most heavy equipment and industrial machinery.
Durable Construction: Built with robust materials to withstand high vibration, extreme temperatures, and harsh operating environments typical of diesel engines.
Enhanced Safety: Provides a positive fuel shut-off, preventing unintended engine operation and reducing the risk of diesel engine runaway.
OEM Standard Quality: Manufactured to match the original Perkins specifications, ensuring consistent performance and long service life.
Versatile Application: Suitable for a wide range of equipment powered by Perkins 400 series engines, including excavators, generators, tractors, and forklifts.
Cost-Effective Solution: Offers a high-quality alternative to expensive dealer parts without compromising on functionality or durability.
Technical Specifications
Specification
Details
Part Number
U85206452
Product Type
Fuel Shut-Off Solenoid Valve
Voltage
12V DC
Engine Type
Diesel
Compatible Engine Models
Perkins 402d, 403c, 403d, 404c
Material
High-Grade Steel & Copper Coil
Weight
1.0 kg (approx.)
Size
OEM Standard Size
Place of Origin
Guangdong, China
Warranty
6 Months
Packing
Plastic Bag, Box, Carton
OEM Cross-Reference
This solenoid valve replaces the following original Perkins part numbers:
U85206452
Note: This part is specifically for the Perkins 400 series engines. Please confirm your existing part number matches before ordering.
Compatibility
This 12V fuel shut-off solenoid is commonly used for the following Perkins diesel engines:
Perkins 402d (2.2L, 4-cylinder)
Perkins 403c (2.2L, 3-cylinder)
Perkins 403d (2.2L, 3-cylinder)
Perkins 404c (2.2L, 4-cylinder)
These engines are widely used in various applications including:
Construction (Mini Excavators, Skid Steer Loaders)
Agriculture (Tractors, Harvesters)
Industrial (Forklifts, Generators)
Marine (Small Vessels, Pumps)
Material Handling (Telehandlers, Boom Lifts)
Fitment Note: This is a commonly used replacement part. Always verify your engine model and existing part number to ensure 100% compatibility.
Global Supply & Distribution
We specialize in the global supply of high-quality diesel engine parts, serving B2B customers worldwide. Our distribution network ensures fast and reliable delivery to major industrial centers and ports across:
North America: USA, Canada, Mexico
Europe: UK, Germany, France, Netherlands, Poland
Asia-Pacific: Australia, New Zealand, Japan, Singapore
Middle East & Africa: UAE, Saudi Arabia, South Africa
South America: Brazil, Chile, Argentina
We offer flexible shipping options including express courier (DHL, FedEx, UPS) and sea freight for bulk orders. All shipments are professionally packed to prevent damage during transit. We also provide full export documentation and customs clearance support for hassle-free international trade.
Quality Assurance
We are committed to providing parts that meet or exceed OEM standards. Our quality assurance process includes:
Manufacturing Standards: Parts are produced in ISO-certified facilities using precision engineering.
Testing: Each solenoid valve undergoes rigorous bench testing for voltage, resistance, and flow control before shipment.
Inspection: We provide Machinery Test Reports and Video Outgoing Inspection upon request to verify quality.
Warranty: This product comes with a 6-month warranty against manufacturing defects.
After-Sales Support: Our technical team offers online support to assist with installation and troubleshooting questions.
FAQ
Q1: How can I confirm this solenoid valve fits my Perkins engine? A: Please check your current solenoid valve for the part number. If it reads U85206452, this is a direct replacement. Also, verify your engine model (402d, 403c, 403d, or 404c) by checking the engine data plate. If you are unsure, contact our support team with your engine serial number for confirmation.
Q2: What are the common symptoms of a failing fuel shut-off solenoid? A: Common signs include: the engine failing to start (no fuel delivery), the engine not shutting off when the key is turned off (run-on), intermittent stalling, or a clicking sound from the solenoid area without proper engagement. If you experience any of these, testing the solenoid’s 12V power supply and resistance is recommended.
Q3: How do I install this solenoid valve? A: Installation is straightforward for a qualified mechanic. First, disconnect the battery negative terminal. Locate the solenoid on the fuel injection pump. Remove the electrical connector and mounting bolts. Install the new solenoid, ensuring the plunger moves freely. Reconnect the wiring harness, ensuring a clean 12V connection. Reconnect the battery and test for proper start/stop function. If the engine does not start, check for air in the fuel system.
Inquiry Form
Send Inquiry
Leave your email and phone / WhatsApp so sales can follow up directly.